top of page
Fort Lauderdale Certified Radon Testing and Mitigation Company.jpg

Fort Lauderdale 
Radon Mitigation System Installation & Testing

EnviroHome specializes in commercial, residential, and multifamily radon testing and mitigation system installations throughout Fort Lauderdale creating individualized project plans tailored by our team of radon certified experts.

Call 786-791-2554 to learn more about the only Florida based company trusted by the Florida Department of Health to train radon professionals!

Fort Lauderdale Radon Levels by Zip Code

The Florida Health department has created a great database, linked here, of radon test results as reported by certified radon businesses and facilities per Florida Statute 404.056. This tool allows you to see the percentage of radon tests that returned greater than a 4 pCi/L result.  The EPA recommends homes and properties be mitigated if the level of radon is above 4 pCi/L.

Below are some of the zip codes in Broward County over 10% that we were able to acquire. Last published: May 21st 2023:

Zip
City
Buildings Measured
Percentage >= 4 pCi/l
33004
DANIA
80
70
33020
HOLLYWOOD
29
13.8
33021
HOLLYWOOD
446
70
33024
HOLLYWOOD
398
27.6
33025
HOLLYWOOD
1687
52.9
33026
PEMBROKE PINES
112
2.7
33027
HOLLYWOOD
75
18.7
33028
PEMBROKE PINES
268
19.8
33082
PEMBROKE PINES
2
50
33304
FORT LAUDERDALE
73
13.7
33309
FORT LAUDERDALE
61
27.9
33311
FORT LAUDERDALE
54
22.2
33312
FORT LAUDERDALE
351
43.6
33313
FORT LAUDERDALE
141
16.3
33314
FORT LAUDERDALE
196
51.5
33319
FORT LAUDERDALE
281
23.1
33321
FORT LAUDERDALE
411
48.7
33322
FORT LAUDERDALE
584
13.7
33324
FORT LAUDERDALE
1425
41.5
33325
FORT LAUDERDALE
126
45.2
33328
FORT LAUDERDALE
220
40.9
33330
PEMBROKE PINES
47
2.1
33351
FORT LAUDERDALE
193
32.6
33441
DEERFIELD BEACH
116
13.8
33442
DEERFIELD BEACH
170
14.7

Per the Florida Department of Health: This radon data does not represent a scientific or statistical survey; therefore, it should be interpreted with caution. The data provides an indication of the radon potential within a zip code if a large enough and properly distributed number of buildings have been tested and reported for the area. This data cannot be used to predict the radon level for existing or new construction. Structural features, construction details, and ventilation operations differ from building to building and greatly influence radon concentration. Structures within the same zip code may have dramatically different indoor radon levels due to these differences. Inferring indoor radon levels for untested buildings based on indoor radon data from tested buildings is not possible.

Up until recently it was believed that there were only two sources of radon exposure – radon gas ground source seepage, and off-gassing of radon impacted groundwater. In the low ground source areas such as Fort Lauderdale, it was generally assumed that radon was not a major concern and not one that would warrant mandatory testing associated real estate transactions, etc. Today we are finding highly elevated radon levels in many South Florida concrete building structures. Test results clearly show that the radon comes from the building materials and specifically from the poured concrete.​

The problem is most significant in Fort Lauderdale condominium, apartments, and high-rise structures where large volumes of formed in-place concrete are used and where large concrete surface areas are present in close proximity to building occupants living in the individual units.  

Our radon testing and mitigation company specializes in radon emanating from building materials. We provide testing, diagnosis, and full scale mitigation plans overseen by certified radon experts, licensed professional engineers, and licensed general contractors to ensure the radon levels in your property are at healthy levels. 

Fort Lauderdale Public School Radon Results

The Florida Department of Health publishes radon test results for state licensed, regulated, owned, or operated facilities. You can find their information linked here and in the table below. If you do not see your school in the table below it's possible a new test has been submitted since we checked on July 31st 2022. Please check the database linked above for your school. If you still do not see your school the best course of action is to call the Radon and Indoor Air Program at 850-245-4288 or 800-543-8279 or email phtoxicology@flhealth.gov

Facility Name
Maximum Radon Level (pCi/L)
Average Radon Level (pCi/L)
Sunset School
1.7
0.925
Thurgood Marshall Elementary School
3.9
2.498462
Virginia Shuman Young Elem School
20.1
2.83
Virginia Shuman Young Elementary
3.9
2.142857
Walker Elementary (Magnet)
3.1
1.4875
Walker Elementary School
0.1
0.057143
Westwood Heights Elementary
1.7
0.690476
Whiddon Rogers Education Center
0.1
0.05
William Dandy Middle School
3.6
1.021008
Wilton Manors Elementary Schl
2.9
1.68125
Wilton Manors Elementary School
0.9
0.283721
Wingate Oaks Center
3.5
1.138889
Arthur Robert Ashe Middle School
1.9
0.961538
Bayview Elementary
3.5
0.855556
Bayview Elementary School
1.9
1.25
Bennett Elementary School
1.6
0.66087
Boyd H Anderson High
3.5
1.880645
Broward Estates Elementary
3.8
1.531579
Broward Estates Elementary School
48
2.442857
Cardinal Gibbons
2.6
1.683333
Country Isles Elementary
1.5
0.635714
Croissant Park Elementary
3.5
0.977174
Croissant Park Elementary School
1.5
1.14
Dillard Elementary
2.2
0.898876
Dillard High
3.5
0.990323
Dillard High School
3.6
1.205882
Eagle Point Elementary
3.9
2.317647
Floranada Elementary
2.5
1
Floranada Elementary School
1.6
0.685714
Fort Lauderdale High School
2.9
0.744828
Ft Lauderdale High School
0.7
0.484615
Gene A Whiddon Adult Center
0.5
0.433333
Harbordale Elementary
1.9
0.885714
Harbordale Elementary School
0.5
0.4
Indian Trace Elementary School
1.7
0.9
Larkdale Elementary School
3.5
1.133333
Lauderdale Manors Elementary
3.2
0.716667
Lauderdale Middle
30.3
3.108333
Martin Luther King Elementary
3.2
1.316
Martin Luther King Elementary School
0.5
0.214286
Meadowbrook Elementary
3.7
1.915385
Meadowbrook Elementary School
0.8
0.518182
New River Middle School
1.1
0.382278
North Andrews Gardens Elementary
1.2
0.534483
North Fork Elementary
1
0.542857
North Fork Elementary School
0.1
0.033333
North Side Elementary
2.1
0.894444
North Side Elementary Annex
2.5
1.671429
North Side Elementary School
0.5
0.204545
Parkway Middle School
2.3
0.6125
Pine Ridge Alternative Center
1.2
0.7
Pine Ridge Education Ctr
2
0.81
Riverland Elementary
3.9
1.089855
Riverland Elementary School
0.4
0.3
Rock Island Elementary School
3.4
1.015625
Seagull School
1.3
0.436364
Stephen Foster Elementary Schl
2.6
1.272727
Stranahan High School
2.8
0.718421
Sun ED High Schoo
0.3
0.3
Sun Ed High School
0.3
0.3
Sunland Park Elementary School
3.7
0.630357
Sunrise Middle School
3.9
1.918987

Per the Florida Department of Health: Radon Testing is required for State licensed, regulated, owned or operated Facilities.  This requirement is the same for all buildings in facilities required to be tested for radon per Florida Statue 404.056.  Currently all buildings in a facility that are used by the clients of the facility are required to be tested twice, five years apart.  Once tested twice, testing is no longer required unless one of the triggering events occurs:

1) a building is subject to significant structural renovation or a change in facility operation equivalent to a building structural change, or
2) the facility legally becomes a new facility.  Examples of a legally new facility would be the issuance of a new license, or there could be a change in ownership or operator.  If a facility operator failed to complete the required testing in any building by the time it was due, the testing should be completed as soon as is practical.

EnviroHome Mitigation System Installation Photos

EnviroHome's Certified Contractor Services

Short Term Radon Test Canister.jpeg

EnviroHome provides radon testing in Florida for real estate transactions, pre and post mitigation system installation testing, and diagnostics. All testing is executed by NRPP certified radon experts.    

Air Vent

If the results of your test show elevated levels of radon, our team of professional engineers will work on a tailored radon mitigation system plan ensuring the post-mitigation indoor levels are below the EPA recommended activity level of 4 pCi/L. 

Image by Niclas Dehmel

​EnviroHome conducts pre-purchase Indoor Air Quality inspections in Florida with equipment and expertise not found with your standard Home Inspector. Ensure prior to your new home purchase that your home does not have an IAQ issue that may reduce your home's value or have negative health effects.

Radon Testing Before Mitigation?

EnviroHome In The News

bottom of page